WEATHERMASTER SUPERFOAM


Titebond WeatherMaster SuperFoam 100, 200 and 600 are low pressure, medium density, two-component spray polyurethane foams. These products are designed to fill and seal various size voids, deaden sound and reduce vibration. SuperFoam’s excellent adhesion properties create a continuous air barrier that helps to improve indoor air qua...

more

Application Guidelines

Coverage:
ITEM DESCRIPTION COVERAGE
85100 WeatherMaster 100 SuperFoam 92 bdft²
85200 WeatherMaster 200 SuperFoam 179 bdft²
85600A WeatherMaster 600 SuperFoam PART A 529 bdft²
85600B WeatherMaster 600 SuperFoam PART B 529 bdft²
Application Directions:
Quick Start SuperFoam 100 & 200
1. Shake kit for one (1) to two (2) minutes to ensure proper mixing.
2. Open kit. Remove nozzle packet and read operating instructions.
3. Open valves. Top flap may be removed or left in place during use or storage. Extend attached gun hose assembly.
4. Before attaching nozzle, apply petroleum jelly on face of gun. After attaching nozzle*, dispense into “test shot receptacle”. Unit is ready to use.
*For detailed nozzle attachment instructions, see Operating Instructions located inside kit.
Application Directions:
Quick Start SuperFoam 600
1. Shake each cylinder for one (1) to two (2) minutes to ensure proper mixing.
2. Open kit. Remove nozzle packet and read operating instructions. Thread red coded hose to A component tank and tighten with a wrench (included). Then, thread black coded hose to B component tank and tighten with a wrench (included).
3. With tanks upright, open tank valves completely. Tank valves must be upright during use.
4. Before attaching nozzle, apply petroleum jelly on face of gun. After attaching nozzle*, dispense into “test shot receptacle.” Unit is ready to use.
*For detailed nozzle attachment instructions, see Operating Instructions located inside kit.
Limitations:
Personal Protective Equipment (PPE) is recommended. This product is extremely flammable when dispensing. Carefully review cautions. Optimum temperature for use is between 40° - 100° F (4° - 38° C). Optimum storage temperature is between 75° - 85°F (24° - 29°C). Clean oil, dust and grease off surfaces to be foamed. Make sure to cover surrounding surfaces. Wear appropriate safety glasses, gloves and protective clothing. Consult SDS for product safety information. For questions, please call our Help Line at 1.800.347.4583 or visit us at Titebond.com.

Physical Properties

Type
Low pressure, medium density, two-component spray polyurethane foam
VOC
<25 g/L
Density
2.0 lb/ft³ (32 kg/m³)
R-value
6.5 per inch
Dimensional Stability
± 5%
Closed-cell Content
92%
Shelf Life (Unopened)
12 months

SPECIFICATIONS

Meets:
  • ASTM D1622; ASTM C518; ASTM E283; ASTM E2178;ASTM D1621; ASTM D2126; ASTM D2856
  • UL GREENGUARD GOLD
  • ASTM E84 - Fire Rating:
    • Tested at 3” Thickness
    • Class 1 (A) Fire Rated
    • Flame Spread Index 10
    • Smoke Developed 450
  • ASTM E96:
    • Perm Rating - Method A
    • 1” Thick (2.54 cm):
    • 1.6 perms - Class III Vapor Retarder

Caution Statement

Low pressure spray polyurethane foams (SPF) are composed of a diisocyanate, hydrofluoroolefin blowing agent, and a polyol. For spray polyurethane foams: wear protective glasses with side shields or goggles, nitrile gloves, and clothing that protects against dermal exposure. Recommend using in well-ventilated area and with certified respiratory protection or a powered air purifying respirator (PAPR). Read the SDS and instructions carefully before use. The urethane foam from these ingredients will support combustion and may present a fire hazard if exposed to a fire or to excessive heat about 240 F (116 C). For professional use only. Building practices unrelated to materials can lead to potential mold issues. Material suppliers cannot provide assurance that mold will not develop in any specific system.

WARNINGS: Follow safety precautions and wear protective equipment as recommended. Prolonged inhalation exposure may cause respiratory irritation/sensitization and/or reduce pulmonary function in susceptible individuals. Onset may be delayed. Pre-existing respiratory conditions may be aggravated. We recommend that the product is used in a well-ventilated area and with certified respiratory protection. NIOSH positive pressure supplied air respirator is recommended if exposure guidelines may be exceeded. Contents may be very sticky and irritating to skin and eyes, therefore wear safety glasses with side shields or goggles, nitrile gloves, and clothing that prevents against dermal exposure while operating. If liquid chemical comes in contact with skin, first wipe thoroughly with dry cloth, then rinse affected area with water. Wash with soap and water afterwards, and apply hand lotion if desired. If liquid chemical comes in contact with eyes, immediately flush with large volumes of water for at least 15 minutes and get medical help at once. If liquid is swallowed, get immediate medical attention. Do not induce vomiting. If breathing is difficult, give oxygen. If breathing has stopped, give artificial respiration. Products manufactured or produced from these chemicals are organic and therefore combustible. Each user of any product should carefully determine if there is a potential fire hazard associated with such product in a specific usage. KEEP OUT OF REACH OF CHILDREN.

Warranty Statement

The Manufacturer warrants only that the product shall meet its specifications: this warranty is in lieu of all other written or unwritten, expressed or implied warranties and The Manufacturer expressly disclaims any warranty of merchantability, or fitness for a particular purpose. The buyer assumes all risks whatsoever as to the use of the material. Buyer’s exclusive remedy as to any breach of warranty, negligence or other claim shall be limited to the replacement of the material. Failure to strictly adhere to any recommended procedures shall release The Manufacturer of all liability with respect to the materials or the use thereof. User of this product must determine suitability for any particular purpose, including, but not limited to, structural requirements, performance specifications and application requirements prior to installation and after product is applied.