Franklin 780 Premium Multi-Purpose Adhesive


Franklin 780 is an environmentally safe latex flooring adhesive with fast tack and a strong permanent bond. It has excellent 24 hour rebond properties. It may be used with conventional carpets, tiles, and resilient sheet goods over standard construction surfaces.

Franklin 780 contains no volatile solvents, no hazardous materials and carcinogens. There is no unpleasant or lingering odor. It is freeze/thaw stable, nonflammable, water-resistant and nontoxic.

Product Features

Physical Properties

Type Latex Calculated VOC 13.6 g/L
Color Beige Flashpoint > 200 °F.(Pensky-Martin Closed Cup)
Weight/gallon 10.1 lbs. Solids 65%
Freeze/thaw stability Stable (5 cycles at 20 °F.) Viscosity Trowel grade
Storage life 24 months in tightly closed container

Trowel recommendations and coverage
Floor Type Trowel Size Coverage
Carpet 3/32" x 3/32" x 3/32" V-notch 15 Sq.Yds./gallon
  1/8" x 1/8" x 1/8" U-notch 11 Sq.Yds./gallon
Tile & Sheet Goods 1/16" x 1/16" x 1/16" Square-notch 150 Sq.Ft./gallon
CLEAN TROWEL WITH WATER OFTEN TO PREVENT ADHESIVE BUILD-UP.

Application Guidelines

Uses Heavy traffic areas for residential, commercial, institutional and industrial installations.
    Carpets: Woven polypropylene, jute, latex unitary, foam and sponge rubber, polyurethane, hot melt, woven and hard unitary backings.
    Tiles:Vinyl composition, asphalt, cork, rubber and fiberglass polyester.
    Resilient Sheet Goods: Mineral, felt, paper and rubber backings.

Substrates Plywood, hardboard, association grade particleboard underlayments, felt lining, moisture and alkali free concrete and asphalt.

Subfloor Preparation All substrates must be clean, dry, structurally sound, properly cured and free of dirt, oil, paint, old adhesive, wax, sealers and curing agents. Subfloor and materials are to be at least 65 °F., prior to and after installation. Concrete subfloors must be structurally sound and free of voids and cracks. Make repairs to concrete substrates to remove unsound or deteriorating areas. If needed, apply cementitious patch to any voids or cracks. Allow cementitious repair materials to cure per cementitious manufacturer’s recommendations. Lightweight concrete or gypsum-based subfloors/materials must have Titebond Concrete Primer (or equivalent) applied prior to use of adhesive. Follow directions of Titebond Concrete primer (or equivalent) before use.

Installation Recommendations For carpets: Use a 3/32" V-notch trowel for smooth and 1/8" U-notch trowel for deep textured backings, or very porous substrates. Open time is between 15 and 30 minutes to promote adhesive transfer. For hard to hold carpet or for adhering to sealed substrates, it will usually be necessary to allow extended open time until glue line becomes tacky to touch before laying goods. Employ a lightweight roller within one hour of installation.
For tile: Use a 1/16" square notch trowel. Open time is between 30 minutes and two hours. Adhesive must transfer to tile backing in order to bond. Employ a 100 pound roller within one hour of installation.
For resilient sheet goods: Use a 1/16" square notch trowel. Open time is 10 and 45 minutes. Adhesive must transfer to backing in order to bond. Immediately after installation employ a linoleum roller.

Cleanup Allow adhesive to dry well before exposing installation to cleaning water. Use water to remove adhesive spots and clean tools.

*CAUTION: Do not sand, scour or abrade any material that is suspected of containing asbestos fibers. Asbestos is known to cause cancer. Federal law requires that asbestos be handled by a licensed and certified hazardous materials contractor.

Limitations

Use in well ventilated area. Do not use over high alkaline concrete (over 9.0 pH) or over subfloor with excessive moisture (over 6 lbs. by calcium chloride test). Do not use directly over or under solid vinyl tile or sheet goods. KEEP FROM FREEZING.

Caution Statements

CAUTION: EYE AND SKIN IRRITANT. Do not swallow. Do not allow eye contact or prolonged skin contact. First Aid: If swallowed, do not induce vomiting, contact physician. If eye contact occurs, flush eyes with water for 15 minutes. Wash skin contact areas with soap and water. If irritation from eye or skin contact areas persist, contact physician. For additional information, refer to Material Safety Data Sheet.
KEEP OUT OF THE REACH OF CHILDREN.

Ordering Information

Part No.SizeWeightUPCCase UPCUnits Per PackagePackages Per Pallet
94344 Gallon Pail42.60  136


Important Notice: Our recommendations, if any, for the use of this product are based on tests believed to be reliable. Since the use of this product is beyond the control of the manufacturer, no guarantee or warranty, expressed or implied, is made as to such use or effects incidental to such use, handling or possession or the results to be obtained, whether in accordance with the directions or claimed so to be. The manufacturer expressly disclaims responsibility therefore. Furthermore, nothing contained herein shall be construed as a recommendation to use any product in conflict with existing laws and/or patents covering any material or use.
2020 Bruck Street, Columbus, Ohio 43207
CUSTOMER SERVICE 1-800-669-4583
TECH SERVICE 1-800-347-4583
www.titebond.com